#ventoy_systemd_udevd_work_around
#ventoy_add_udev_rule "$VTOY_PATH/hook/default/udev_disk_hook.sh %k noreplace"
+if [ -f $VTOY_PATH/autoinstall ]; then
+ VTKS="inst.ks=file:$VTOY_PATH/autoinstall"
+else
+ for vtParam in $($CAT /proc/cmdline); do
+ if echo $vtParam | $GREP -q 'ks=file:/'; then
+ continue
+ fi
+
+ if echo $vtParam | $GREP -q 'inst.ks=hd:LABEL='; then
+ vtRawKsFull="$vtParam"
+ vtRawKs=$(echo $vtParam | $AWK -F: '{print $NF}')
+ VTKS="inst.ks=hd:/dev/ventoy:$vtRawKs"
+ break
+ fi
+
+ if echo $vtParam | $GREP -q '^ks=.*:/'; then
+ vtRawKsFull="$vtParam"
+ vtRawKs=$(echo $vtParam | $AWK -F: '{print $NF}')
+ VTKS="ks=hd:/dev/ventoy:$vtRawKs"
+ break
+ fi
+
+ if echo $vtParam | $GREP -q '^inst.ks=.*:/'; then
+ vtRawKsFull="$vtParam"
+ vtRawKs=$(echo $vtParam | $AWK -F: '{print $NF}')
+ VTKS="inst.ks=hd:/dev/ventoy:$vtRawKs"
+ break
+ fi
+ done
+fi
+
+if [ -f $VTOY_PATH/ventoy_persistent_map ]; then
+ VTOVERLAY="rd.live.overlay=/dev/dm-1:/vtoyoverlayfs/overlayfs"
+
+ if [ -e /sbin/dmsquash-live-root ]; then
+ echo "patch /sbin/dmsquash-live-root for persistent ..." >> $VTLOG
+ $SED "/mount.*devspec.*\/run\/initramfs\/overlayfs/a . /ventoy/hook/rhel7/ventoy-overlay.sh" -i /sbin/dmsquash-live-root
+ $SED "s/osmin.img/osmin.imgxxxx/g" -i /sbin/dmsquash-live-root
+ fi
+
+ #close selinux
+ $BUSYBOX_PATH/mkdir -p $VTOY_PATH/selinuxfs
+ if $BUSYBOX_PATH/mount -t selinuxfs selinuxfs $VTOY_PATH/selinuxfs; then
+ echo 1 > $VTOY_PATH/selinuxfs/disable
+ $BUSYBOX_PATH/umount $VTOY_PATH/selinuxfs
+ fi
+ $BUSYBOX_PATH/rm -rf $VTOY_PATH/selinuxfs
+fi
+
+echo "VTKS=$VTKS VTOVERLAY=$VTOVERLAY" >> $VTLOG
+
+if [ -n "$vtRawKs" ]; then
+ if echo $vtRawKsFull | $EGREP -q "=http|=https|=ftp|=nfs|=hmc"; then
+ echo "vtRawKsFull=$vtRawKsFull no patch needed." >> $VTLOG
+ vtRawKs=""
+ VTKS=""
+ else
+ echo "$vtRawKs" > $VTOY_PATH/ventoy_ks_rootpath
+ fi
+fi
+
+if ls $VTOY_PATH | $GREP -q 'ventoy_dud[0-9]'; then
+ for vtDud in $(ls $VTOY_PATH/ventoy_dud*); do
+ vtInstDD="$vtInstDD inst.dd=file:$vtDud"
+ done
+fi
+echo "vtInstDD=$vtInstDD" >> $VTLOG
+
if $GREP -q 'root=live' /proc/cmdline; then
- $SED "s#printf\(.*\)\$CMDLINE#printf\1\$CMDLINE root=live:/dev/dm-0#" -i /lib/dracut-lib.sh
+ $SED "s#printf\(.*\)\$CMDLINE#printf\1\$CMDLINE root=live:/dev/ventoy $VTKS $VTOVERLAY $vtInstDD#" -i /lib/dracut-lib.sh
else
- $SED "s#printf\(.*\)\$CMDLINE#printf\1\$CMDLINE inst.stage2=hd:/dev/dm-0#" -i /lib/dracut-lib.sh
+ $SED "s#printf\(.*\)\$CMDLINE#printf\1\$CMDLINE inst.stage2=hd:/dev/ventoy $VTKS $VTOVERLAY $vtInstDD#" -i /lib/dracut-lib.sh
fi
ventoy_set_inotify_script rhel7/ventoy-inotifyd-hook.sh
-$BUSYBOX_PATH/cp -a $VTOY_PATH/hook/rhel7/ventoy-inotifyd-start.sh /lib/dracut/hooks/pre-udev/01-ventoy-inotifyd-start.sh
+#Fedora
+if $BUSYBOX_PATH/which dmsquash-live-root > /dev/null; then
+ vtPriority=99
+else
+ vtPriority=01
+fi
+
+$BUSYBOX_PATH/cp -a $VTOY_PATH/hook/rhel7/ventoy-inotifyd-start.sh /lib/dracut/hooks/pre-udev/${vtPriority}-ventoy-inotifyd-start.sh
+$BUSYBOX_PATH/cp -a $VTOY_PATH/hook/rhel7/ventoy-timeout.sh /lib/dracut/hooks/initqueue/timeout/${vtPriority}-ventoy-timeout.sh
+
+vtNeedRepo=
+if [ -f /etc/system-release ]; then
+ if $GREP -q 'RED OS' /etc/system-release; then
+ vtNeedRepo="yes"
+ fi
+fi
+
+if $GREP -q 'el[89]' /proc/version; then
+ vtNeedRepo="yes"
+fi
+
+if $GREP -i -q Fedora /proc/version; then
+ if $GREP -q 'Server Edition' /etc/os-release; then
+ vtNeedRepo="yes"
+ fi
+fi
+
+echo "vtNeedRepo=$vtNeedRepo" >> $VTLOG
+
+if [ "$vtNeedRepo" = "yes" ]; then
+ $BUSYBOX_PATH/cp -a $VTOY_PATH/hook/rhel7/ventoy-repo.sh /lib/dracut/hooks/pre-pivot/99-ventoy-repo.sh
+fi
+
+if [ -e /sbin/dmsquash-live-root ]; then
+ echo "patch /sbin/dmsquash-live-root ..." >> $VTLOG
+ $SED "1 a $BUSYBOX_PATH/sh $VTOY_PATH/hook/rhel7/ventoy-make-link.sh" -i /sbin/dmsquash-live-root
+fi
# suppress write protected mount warning
if [ -e /usr/sbin/anaconda-diskroot ]; then
$SED 's/^mount $dev $repodir/mount -oro $dev $repodir/' -i /usr/sbin/anaconda-diskroot
fi
+#For Fedora CoreOS
+if $GREP -i -q 'fedora.*coreos' /etc/os-release; then
+ $SED "s#isosrc=.*#isosrc=/dev/mapper/ventoy#" -i /lib/systemd/system-generators/live-generator
+ cp -a $VTOY_PATH/hook/rhel7/ventoy-make-link.sh /lib/dracut/hooks/pre-mount/99-ventoy-premount-mklink.sh
+fi
+
+if [ -f $VTOY_PATH/autoinstall ]; then
+ cp -a $VTOY_PATH/hook/rhel7/ventoy-autoexp.sh /lib/dracut/hooks/pre-mount/99-ventoy-autoexp.sh
+fi